Skip to main content
. 2015 Nov 7;17(41):27380–27390. doi: 10.1039/c5cp04352b

Table 2. Best-fit average lifetimes (τ in ns) and energy transfer efficiencies (E ET, calculated from eqn (1)) at 293 K and 310 K for the excited state quenching of 2 by 32+ at different 32+ mole fractions in PEGylated (4 mol%) DMPC vesicles, as measured with transient absorption (TA) spectroscopy and time-correlated single photon counting (TCSPC). All liposomes had a fixed amount of compound 2 (0.5 mol%). Transient absorption spectroscopy data was globally fitted using the software package Glotaran.50 Full datasets are given in ESI, as well as detailed information on data analysis.

  Molar percentage of 32+ in PEGylated DMPC liposomes
0.0 0.4 0.8 1.7 2.5 3.3
TA spectroscopy at 293 K
τ 6.00 ± 0.10 3.03 ± 0.02 1.52 ± 0.01 1.04 ± 0.01 0.40 ± 0.00 0.29 ± 0.00
E ET (%) 0 50 75 83 93 95
  32+ molar percentage in PEGylated DMPC liposomes
0.0 0.5 0.9 1.7 2.4 3.5
TCSPC at 293 K
τ 6.17 ± 0.01 4.67 ± 0.01 2.50 ± 0.05 1.29 ± 0.02 1.25 ± 0.05 0.85 ± 0.06
E ET (%) 0 24 60 79 80 86
TCSPC at 310 K
τ 5.69 ± 0.01 4.00 ± 0.01 2.37 ± 0.07 1.14 ± 0.00 0.84 ± 0.00 0.45 ± 0.00
E ET (%) 0 30 58 80 85 92