Skip to main content
. Author manuscript; available in PMC: 2017 Jan 1.
Published in final edited form as: Neuroimage. 2015 May 12;124(0 0):1120–1124. doi: 10.1016/j.neuroimage.2015.05.005

Table 2.

Image Scanning Parameters for PSHMC

T1-weighted T2-weighted Susceptibility
weighted (R2*)
Diffusion weighted

Sequence MP-RAGE FSE Multi-gradient-echo EPI
TR (ms) 1540 2500 54 8300
TE (ms) 2.34 316 6 echoes:7–47ms Interval: 8 82
Flip Angle 9 120 20 90
Inversion time (ms) 807
b value (s/mm2) - - - 1000
Diffusion directions - - - 42 & 7
Resolution (mm3) 1×1×1 1×1×1 1×1×1 2×2×2
Thickness (mm) 1 1 2 2
Field of View 256 × 256 256 × 256 256 × 256 256 × 256
Number of Slices 176 176 64 65
Imaging direction Sagittal Sagittal Axial Axial

MP-RAGE = magnetization prepared-rapid acquisition gradient echo; TE = echo time; TR = repetition time; EPI = echo planar image