Skip to main content
. 2015 Nov 12;9(6):064102. doi: 10.1063/1.4935937

FIG. 4.

FIG. 4.

Characterization of the burst pressure at which liquid leaks with strain induced from the inner diameters of the dispenser plug. The data were obtained from five repeated experiments in the pressure range of 0–200 kPa, with increments of 20 kPa.