Table 1.

Initial parameter values for the fully hyperviscoelastic model fitting. Each parameter was scaled such that the initial values all shared the same order of magnitude. All αn, βn, and ωn parameters are unit less.

Parameter a2 [kPa] a4 [kPa] α 1, 2, 3 β 1, 2, 3 μ1, 2, 3 [s] ω 1, 2, 3
Initial Value 10 1000 0.5, 0.25, 0.15 0 0.1, 10, 100 0