Comparison of the activity of H2-driven acetophenone reduction using particles modified with hydrogenase, NAD+ reductase and ADH in the presence of different cofactor concentrations

Entry [NAD+] [mm] Turnover frequency[a] Turnover number[b] Total turnover number[c] Conversion [%][d]
1 1 1.41 9.85 135 000 >98
2 0.1 0.88 84.4 116 000 84
3 0.01 0.20 655 90 000 66

[a] Moles of phenylethanol per second per mole NAD+ reductase recorded over the first 6 h; [b] Moles of phenylethanol per mole cofactor after 21.5 h; [c] Moles of phenylethanol per mole NAD+ reductase after 21.5 h; [d] Conversion [%] after 21.5 h. Conditions: samples were shaken during reaction, with H2 (1 bar) flowing through the headspace; 10 mm acetophenone, Tris-HCl buffer, pH 8, 25 °C.