Table 1.
Absolute agreement with drill size | |||
---|---|---|---|
ICC α | 95% CI β | ||
2D CT | Mean | 0.922 | [0.713 to 0.97] |
Coronal | 0.876 | [0.711 to 0.942] | |
Axial | 0.907 | [0.548 to 0.968] | |
Sagittal | 0.876 | [0.759 to 0.936] | |
3D Model | Best fit transverse section | 0.899 | [0.784 to 0.938] |
Best fit cylinder | 0.745 | [0.553 to 0.862] | |
Wall Thickness | −0.004 | [−0.081 to 0.12] |
Shows the intraclass correlation coefficient (ICC) and respective confidence intervals range ([95%CI]) for the CT and 3D model first measurements compared to the drill sizes.
αICC (intraclass correlation coefficient).
β95% CI (95% confidence intervals range).