Table 2. Flexural strength (σ, MPa) and Flexural Modulus (Eflexural, GPa) for the 2 mm and 4 mm sample groups.
| Flexural strength (σ, MPa) | Flexural Modulus (Eflexural, GPa) | |||
|---|---|---|---|---|
| 2 mm | 4 mm | 2 mm | 4 mm | |
| SonicFill | 157 ± 16K | 147 ± 20k | 12.4 ± 1.6A | 6.5 ± 0.5a* |
| EverX Posterior | 153 ± 9K | 140 ± 14kl | 14.6 ± 1.6A | 6.9 ± 0.5a* |
| X-tra base | 150 ± 8K | 124 ± 13lm | 10.7 ± 1.3A | 5.7 ± 0.4b* |
| Filtek bulk fill | 139 ± 9KL | 139 ± 9kl | 6.3 ± 0.4B | 4.0 ± 0.1c* |
| Surefil SDR | 129 ± 13LM | 121 ± 19lm | 7.2 ± 1.2B | 3.9 ± 0.4c* |
| Tetric evoceram bulk fill | 118 ± 11L | 112 ± 26l | 10.8 ± 0.6A | 5.6 ± 0.2b* |
| Venus bulk fill | 116 ± 5L | 121 ± 10l | 5.0 ± 0.4B | 2.8 ± 0.2d* |
Uppercase letters identify statistically homogenous groups for 2 mm thickness samples. Lower case letters identify statistically homogenous groups for 4 mm thickness samples. Asterisks identify statistical difference between 2 mm and 4 mm thickness samples of the same material (p < 0.05).