Skip to main content
. 2015 Feb 17;88(1048):20140612. doi: 10.1259/bjr.20140612

Table 3.

Dosimetric parameters for organ at risk sparing (without boost)

Variable Technique
Conv FIF HT-IMRT TD-3DCRT TD-IMRT
Heart
 Max. (Gy) 49.99 (1.57) 47.09 (6.01) 42.88 (6.61) 50.19 (12.13) 48.11 (13.50)
 Min. (Gy) 2.51 (2.60) 0.61 (0.21) 1.57 (0.32) 0.78 (0.12) 0.70 (0.11)
 Mean (Gy) 5.33 (1.67) 3.67 (2.59) 4.68 (0.96) 3.65 (1.96) 3.38 (2.04)
V40 2.39 (2.95) 2.99 (4.62) 0.20 (0.32) 2.49 (2.89) 2.31 (3.18)
V30 3.25 (3.37) 3.84 (5.25) 1.04 (1.10) 3.27 (3.36) 3.08 (3.71)
V20 4.15 (3.75) 4.65 (5.74) 2.77 (1.90) 4.10 (3.86) 3.93 (4.26)
V10 5.79 (4.36) 5.89 (6.35) 7.44 (3.57) 5.41 (4.68) 5.16 (5.07)
V5 19.04 (8.51) 8.17 (7.21) 19.33 (7.24) 7.25 (5.90) 6.81 (6.04)
Total lung
 Max. (Gy) 51.24 (1.23) 49.68 (1.5) 50.16 (2.07) 53.35 (1.49) 52.72 (1.26)
 Min. (Gy) 0.391 (0.30) 0.17 (0.13) 0.93 (0.348) 0.38 (0.89) 0.35 (0.07)
 Mean (Gy) 6.75 (1.21) 5.86 (1.81) 5.99 (0.981) 5.30 (0.76) 4.76 (1.06)
V40 5.51 (1.87) 5.73 (2.97) 0.97 (0.72) 5.18 (1.19) 4.17 (1.75)
V30 7.36 (2.02) 7.98 (3.35) 3.67 (1.18) 6.93 (1.33) 5.91 (1.91)
V20 9.03 (2.23) 9.63 (3.66) 7.25 (1.65) 8.57 (1.42) 7.56 (2.02)
V10 13.52 (3.28) 12.64 (4.36) 14.13 (2.44) 11.33 (1.69) 10.28 (2.38)
V5 26.55 (6.93) 19.09 (6.11) 26.37 (7.70) 15.80 (2.20) 14.34 (2.94)

3DCRT, three-dimensional conformal radiotherapy; conv, conventional; FIF, field in field; HT, helical tomotherapy; IMRT, intensity-modulated radiotherapy; max., maximum; min., minimum; TD, TomoDirect™ (Accuray Inc., Sunnyvale, CA); Vx, volume of OAR receiving at least x Gy.

The values in the table are expressed as mean (standard deviation).