Skip to main content
. 2015 Jul 11;28(6):535–545. doi: 10.1007/s10334-015-0495-2

Table 4.

Volume measurement of each plaque component and vessel wall at scan–rescan sessions

Plaque component Volume measured with manual segmentation (mean ± SD) Volume measured with automatic segmentation (mean ± SD)
First scan (1st) Second scan (2nd) Difference (1st–2nd) First scan (1st) Second scan (2nd) Difference (1st–2nd)
Fibrous tissue (mm3) 562.2 ± 354.5 560.6 ± 351.2 1.7 ± 108.0 569.6 ± 263.3 551.4 ± 265.2 18.3 ± 100.8
Lipid (mm3) 44.1 ± 75.1 33.7 ± 8.9 10.4 ± 64.8 28.6 ± 64.1 30.7 ± 83.2 −2.1 ± 26.1
Calcification (mm3) 82.9 ± 121.8 83.1 ± 145.2 −0.2 ± 55.3 85.4 ± 189.6 78.8 ± 175.2 6.6 ± 65.7
Loose matrix (mm3) 80.5 ± 101.4 61.1 ± 90.4 19.4 ± 104.3 86.2 ± 132.2 83.4 ± 110.9 2.8 ± 61.1
Vessel wall (mm3) 779.7 ± 570.4 750.9 ± 521.5 28.8 ± 161.9

For each type of tissue, the mean volume was calculated by taking the average from all 23 patients, in whom the post-aligned scan and rescan data were used