Skip to main content
. 2015 Oct 30;21(21-22):2703–2713. doi: 10.1089/ten.tea.2015.0183

FIG. 4.

FIG. 4.

Scaffold seeding comparison. A seeding comparison was performed between static (pipetting directly onto the scaffolds), suspension (immersing the scaffolds in suspensions containing the cells), or dynamic seeding (in the rotating bioreactor). The bioreactor, at a speed removing the gravitational component, had the highest rate of cell seeding as determined using MTS (A) and cell counting assays (B). *p-value <0.05 when compared to static group. Color images available online at www.liebertpub.com/tea