Table3.
Biomechanical parameter values used in previous studies for lung modeling.
Previous research | Biomechanical parameters | |
---|---|---|
Poisson’s ratio | Young’s Modulus | |
(West and Matthews, 1972) | 0.2 to 0.48 | 0.25 kPa |
(Sundaram and Feng, 1977) | 0.45 | 0.25 kPa |
(De Wilde et al., 1981) | 0.3, 0.4, and 0.45 | 0.73 kPa |
(Zhang et al., 2004) | 0.35 | 4.0 kPa |
(Brock et al., 2005) | 0.45 | 5.0 kPa |
(Villard et al., 2005) | 0.25, 0.3, and 0.35 | 0.25 to 7.0 kPa |
(Eom et al., 2010) | 0.4 | 6.0 kPa |