Table 5.

Values of TCM motion simulation error along left-right (LR), anterior-posterior (AP) and superior-inferior (SI) directions in phase 0%.

Patient # Tumor motion
range between
phase 0% and phase
50% (mm)
TCM error in isotropic
elastic model (mm)
phase 0%
TCM error in Neo-
Hookean model (mm)
phase 0%
TCM error in Mooney-
Rivlin model (mm)
phase 0%

Direction LR AP SI LR AP SI LR AP SI LR AP SI
1 0.5 2.07 6.07 −0.84 −1.14 −1.99 −1.05 −0.48 0.73 −1.10 −0.24 0.61
2 2.63 3.56 14.22 −2.16 −2.07 −7.79 −1.91 −0.63 −1.63 −1.29 −0.35 −1.69
3 1.70 5.44 1.55 0.23 −1.86 −0.73 0.05 −1.74 −0.24 −0.01 −1.66 −0.18
4 0.96 0.18 6.98 −0.26 0.12 −4.35 −0.18 0.15 −2.63 −0.20 −0.19 −2.63
5 0.82 1.11 7.96 −1.83 −3.41 1.69 −1.33 −2.93 1.24 −1.30 −2.76 1.10
6 1.58 6.41 1.43 1.00 −0.10 1.97 0.93 −0.4 2.07 0.92 −0.53 1.94
7 0.98 0.63 12.46 0.98 −0.02 −4.09 0.89 −1.00 0.95 1.08 −0.75 1.01
8 1.01 0.14 7.02 −1.50 0.8 −4.13 −0.51 −0.42 −3.00 −0.50 −0.40 −2.99

Mean 1.27 2.44 7.21 −0.54 −0.96 −2.42 −0.38 −0.93 −0.31 0.30 −0.86 −0.35