Skip to main content
. 2015 Nov 19;9:624. doi: 10.3389/fnhum.2015.00624

Table 2.

Characteristics of sleep spindles detected by all scorers (consensus) and of spindles detected only by a single scorer in stage 2 sleep.

Consensus (N = 1556) Mean (SD) Only CWT (N = 726) Mean (SD) Only SIESTA (N = 583) Mean (SD) Only Human (N = 243) Mean (SD)
Spindle 12.51 (3.46) 8.54 (2.30) 9.24 (3.54) 7.92 (4.00)
amplitude (μV)a
Spindle 13.75 (1.15) 11.94 (1.74) 13.10 (1.23) 12.05 (2.70)
frequency (Hz)
Spindle 0.88 (0.33) 0.81 (0.42) 0.74 (0.41) 0.99 (0.47)
length (s)
Delta (μV)b 6.74 (4.16) 10.22 (7.44) 7.26 (4.74) 7.45 (6.38)
Theta (μV)b 4.61 (2.30) 6.56 (4.22) 4.82 (2.95) 5.95 (4.93)
Alpha (μV)b 3.80 (1.94) 5.10 (2.33) 4.34 (3.18) 6.27 (3.98)
Spindle to 2.56 (1.15) 1.22 (0.58) 1.73 (0.72) 1.22 (0.64)
background ratioc

Sleep spindles were scored in the C3A2 EEG channel. aComputed from amplitude spectrum as described in “Computation of Sleep Spindle Amplitude and Frequency” Section. bMean amplitude in chosen frequency from amplitude spectrum (delta: 2–4.5 Hz, theta: 4.6–7.5 Hz, alpha: 7.6–11 Hz). cSpindle amplitude divided by mean amplitude in 2–11 Hz background frequency computed from amplitude spectrum.