Dose constraints for radiotherapy plans

Dose Constraints
Dose-volume constraints
PTV1 (50 Gy) V95% (47.5 Gy) > 95 %
Dmax (0.1 cc) < 107 % (53.5 Gy)
PTV2 (60 Gy) V95% (57 Gy) > 95 %
Dmax (0.1 cc) < 107 % (64.2 Gy)
Lung Mean dose < 20 Gy
V20Gy < 25 %
Heart Mean dose < 25 Gy
V30Gy < 45 %a
V40Gy < 30 %b
CordPRV Dmax (0.1 cc) < 40 Gy (45 Gy permitted)
Liver V30Gy < 60 %
Individual Kidneys V20Gy < 25 %
StomachInc Max dose < 60Gy
StomachOutc Max dose < 45Gy

aApplies only to 50GyRA and 60GyRA plans

bApplies only to 50Gy3D plans

cApplies only to 60GyRA plans