Published in final edited form as: Med Dosim. 2014 Aug 22;40(1):21–25. doi: 10.1016/j.meddos.2014.06.007

Table 4.

Ideal dose-volume criteria for ipsilateral lung and corresponding achieved values (averages and standard deviations). The averages and standard deviations were calculated separately for supine and prone for relevant plan options with data from applicable cases.

Plan Options V16Gy≤15% V8Gy≤35% V4Gy≤50%

Supine Prone Supine Prone Supine Prone
3D+3D 12.6±2.5 3.3±2.7 19.0±3.9 5.1±3.8 32.7±10.6 7.4±5.2
3D+e 12.6±2.4 18.3±3.7 27.6±6.8
3D+IMRT 12.2±2.2 3.5±2.7 17.7±2.8 5.2±3.7 30.0±9.4 7.7±4.6
IMRT+3D 12.7±1.6 3.3±2.5 19.2±3.0 4.7±3.3 33.7±10.7 6.7±4.5
IMRT+e 13.1±1.9 19.2±3.8 30.0±9.7
IMRT+IMRT 12.7±1.6 3.3±2.5 18.5±2.8 4.7±3.4 30.3±9.1 6.7±4.5
SIB 12.7±2.0 3.4±2.7 18.0±3.8 4.8±3.5 25.3±7.1 6.9±4.7