Skip to main content
. Author manuscript; available in PMC: 2015 Nov 23.
Published in final edited form as: Acta Biomater. 2014 Aug 14;10(11):4639–4649. doi: 10.1016/j.actbio.2014.08.008

Table 2.

Mechanical properties of PEUU-NH2 and PEUU-PC under dry and wet conditions, and water absorption of dry films.

Polymer Strain at
break (%)
Tensile strength
at break (MPa)
Initial modulus
(MPa)
Water
absorption (%)

Dry Wet Dry Wet Dry Wet
PEUU-N1 823 ± 27a 693 ± 35b 25.5 ± 6.7a 29.8 ± 3.0a 13.0 ± 2.7ab 15.0 ± 1.6a 2.6 ± 0.4a
PEUU-PC1 735 ± 14b 485 ± 35c 38 ± 1.4a 13.6 ± 1.1b 15.2 ± 1.2a 10.3 ± 0.5b 17.3 ± 0.6b
PEUU-N2 685 ± 20 30.4 ± 3.6 18.8 ± 2.8 4.6 ± 1.1
PEUU-N3 600 ± 24a 530 ± 15b 34.4 ± 1.8b 28.1 ± 2.1c 26.6 ± 2.6a 17.3 ± 1.7b 7.8 ± 1.0a
PEUU-PC3 508 ± 26b 421 ± 30c 41 ± 3.0a 15.0 ± 2.8d 27 ± 3.1a 10.7 ± 0.9c 27.0 ± 1.5b
PEUU-N5 370 ± 17a 153 ± 40b 29.6 ± 2.8b 10.1 ± 2.3c 49.0 ± 3.5a 20.1 ± 2.6b 8.8 ± 0.8a
PEUU-PC5 370 ± 19a 110 ± 23b 38 ± 4.2a 5.3 ± 0.5c 43 ± 2.3a 10.7 ± 0.9c 38.4 ± 0.9b
PEUU-N10 246 ± 27 35.4 ± 2.7 140.6 ± 12.3 12.2 ± 0.7

Statistical comparisons were made amongst each PEUU-NH2 type with a corresponding PEUU-PC type under dry and wet conditions. a, b, c and d denote statistically distinct groups for each measured parameter, including dry & wet, within a given set of PEUU-NH2 and corresponding PEUU-PC polymers.