Skip to main content
. 2014 Mar 1;12(2):110–119. doi: 10.1089/adt.2013.552

Table 3.

Multiple Mode Voltage Protocol Parameters

Ion channel Holding potential (mV) CP potential (mV) CP duration (s) TP potential (TP1–TP32, mV) TP duration (TP1–TP32, ms) TP frequency (TP3–TP32, Hz)
Cav1.2 −90 −50 60 10 250 0.1
Cav2.1 −90 −50 60 10 400 0.1
Cav2.2 −90 −50 60 30 400 0.1
Cav3.2 −90 −75 60 −30 200 1

CP, conditioning prepulse; TP, test pulse.