Skip to main content
Journal of Dentistry (Tehran, Iran) logoLink to Journal of Dentistry (Tehran, Iran)
. 2015 Apr;12(4):281–289.

Effect of Four Methods of Surface Treatment on Shear Bond Strength of Orthodontic Brackets to Zirconium

Soghra Yassaei 1, Hossein Agha Aghili 2, Abdolrahim Davari 3, Seyed Morteza Saadat Mostafavi 4,
PMCID: PMC4662766  PMID: 26622283

Abstract

Objectives:

Providing reliable attachment between bracket base and zirconia surface is a prerequisite for exertion of orthodontic force. The purpose of the present study was to evaluate the effect of four zirconium surface treatment methods on shear bond strength (SBS) of orthodontic brackets.

Materials and Methods:

One block of zirconium was trimmed into four zirconium surfaces, which served as our four study groups and each had 18 metal brackets bonded to them. Once the glazed layer was removed, the first group was etched with 9.6% hydrofluoric acid (HF), and the remaining three groups were prepared by means of sandblasting and 1W, and 2W Er: YAG laser, respectively. After application of silane, central incisor brackets were bonded to the zirconium surfaces. The SBS values were measured by a Dartec testing machine with a crosshead speed of 1 mm/min. Data were analyzed using one-way ANOVA and Tukey’s HSD for multiple comparisons.

Results:

The highest SBS was achieved in the sandblasted group (7.81±1.02 MPa) followed in a descending order by 2W laser group (6.95±0.87 MPa), 1W laser group (6.87±0.92 MPa) and HF acid etched group (5.84±0.78 MPa). The differences between the study groups were statistically significant except between the laser groups (P<0.05).

Conclusion:

In terms of higher bond strength and safety, sandblasting and Er: YAG laser irradiation with power output of 1W and 2W can be considered more appropriate alternatives to HF acid etching for zirconium surface treatment prior to bracket bonding.

Keywords: Lasers, Solid-State; Shear Strength; Hydrofluoric Acid; Zirconium

INTRODUCTION

At present, the number of adults seeking orthodontic treatment is increasing. Many of them present to orthodontic clinics with restorations such as crowns and bridges in their mouth, made of yttrium-stabilized tetragonal zirconia (Y-TZP) ceramics or in short, zirconium crowns. These crowns are widely used and favored for their advantages including biocompatibility, aesthetics, cost effectiveness, fracture resistance, and accurate fabrication. Zirconia crowns are used to restore posterior teeth and occasionally anterior teeth when the focus is more on strength rather than aesthetics [1].

Providing reliable attachment between bracket base and zirconia surface is a prerequisite for exertion of orthodontic force. This attachment should be strong enough to prevent bond failure in the course of orthodontic treatment and maintain the uniformity of zirconia following debonding.

Since zirconia is a member of porcelain family, orthodontists use the same methods for preparation of zirconium crowns before bracket bonding as they do for porcelain surfaces [24]. Among these methods, the most utilized one is HF acid etching, which has the disadvantages of producing toxic vapors and burning skin and mucous membranes. Furthermore, it may damage the zirconia surfaces. Therefore, finding an alternative method to HF acid etching with fewer side effects on soft tissues and restoration surfaces seems to be necessary. Er: YAG laser irradiation is a new method appreciated by many authors for its advantages in preparing the enamel and porcelain surfaces [2,4, 5]. It is a solid laser with a wavelength of 2,940 nm in the infrared range. Sandblasting is another method for preparation of various non-enamel surfaces.

Therefore, the objective of this study was to compare the effect of four methods of zirconium surface preparation, including 10% HF acid etching, Er: YAG laser irradiation with power outputs of 1 and 2 W and sandblasting on SBS of metal brackets to find an appropriate method of zirconia preparation for orthodontic bonding.

MATERIALS AND METHODS

In the present study, one round block of full contour zirconia (yttrium-stabilized tetragonal zirconia ceramic, Zircon Zhan, Prettau, Italy), 95 mm in diameter and 22 mm in height, was used. Using a special burr, the block of full contour zirconia was trimmed into two half-round blocks, which were simultaneously glazed in an oven in a similar fashion. Consequently, we had two half-round blocks, each having two surfaces on their sides.

Thus, we had four zirconia surfaces for bracket bonding. Each of these surfaces served as a study group, prepared differently and had 18 metal brackets bonded to it. Initially the glazed layer of the zirconia was removed using a 0.8 mm round bur. A rectangular outline with a diameter of 12 mm was then marked on zirconia surfaces using nail varnish for bonding of each bracket.

The brackets were arranged so that 10 mm distance was considered between them from each side.

To have the laser operate at its most appropriate power output, four additional square samples of zirconia with a diameter of 16 mm were tested in a pilot study.

The first three specimens were Er: YAG laser (Fontona–1210 Ljubljana, Slovenia) irradiated with an average power output of 1, 2, and 4 W and were compared to the fourth sample, which was prepared using HF acid etching. The four samples were examined under an scanning electron microscope (SEM) (VEGA, Tescan, PA, USA) and considering the burning on the sample lased with 4W Er: YAG (Fig. 1) and the appropriate etching pattern observed in other specimens (Figs. 24), it was decided to use the power settings of 1 and 2 W for laser groups in the current study. Regarding surface conditioning, the zirconia surface in group one was etched using 9.6% HF acid (Pulpdent, Watertown, USA). Following two-minute application of acid on the zirconium surface, it was washed with a gentle flow of water for 10 seconds and later dried by a blower for 10 seconds.

Fig. 1.

Fig. 1.

SEM micrograph of the burning of the sample lased with 4W Er: YAG laser at ×1000 magnification.

Fig. 2.

Fig. 2.

SEM micrograph of the sample prepared using hydrofluoric acid at ×1000 magnification.

Fig. 4.

Fig. 4.

SEM micrograph of the sample lased with 1 W laser (×1000 magnification).

Fig. 3.

Fig. 3.

SEM micrograph of the sample lased with 2 W laser (×1000 magnification)

The zirconia surface in the second group was sandblasted (Renfert, Hilzingen, Germany) with 110 μm aluminum oxide particles at 80 Psi pressure for four seconds.

The zirconia surfaces in groups three and four were prepared using Er: YAG laser irradiation. Therefore, group three samples were exposed to 1 W power, 50 MJ energy, 20 Hz frequency and 416 MJ/cm2 energy density for 60 seconds. The group four samples were exposed to 2 W power, 100 MJ energy, 20 Hz frequency and 832 MJ/cm2 energy density for 60 seconds.

Pattern of movement of laser tip was linear by hand and the time of lasing was calculated with a stopwatch.

The fiber tip of laser headpiece was held at 10 mm distance from the fixed samples.

Then, the surface of the prepared samples was smeared with silane (Pulpdent, Watertown, USA) and dried. Stainless steel standard edgewise maxillary central brackets (Dentsply Gac, NY, USA) were used in this study.

The bracket bases were covered with a thin layer of light curing composite resin (Resilience, Ortho Technology Inc., FA, USA) and placed on their pre-specified places.

Once the brackets were placed, curing process was done using 1000 W light emitting diode (LED) light curing unit (Morita, Kyoto, Japan) for 20 seconds (five seconds for each of the occlusal, gingival, mesial, and distal surfaces).

The LED tip was held at the closest possible distance to the samples at a 45-degree angle. Before curing of each bracket, the other 17 brackets were covered with aluminum foil to protect them from extra curing. Following bracket bonding, the zirconia samples were stored in water at 37° for 24 hours. They were then subjected to 500 thermal cycles between 5 and 55°C for 30 seconds with a transfer time of 15 seconds. After thermocycling, debonding was performed using a Dartec testing machine (HC10, Dartec Ltd., Sturbridge, England) with a crosshead speed of 1 mm/min and 0.5 mm blade thickness. For this purpose, samples were fixed and tip of the Dartec testing machine was moved forward at the bracket-zirconium interface until the bond failure. The SBS was then calculated as the maximum force applied divided by the surface area and recorded in megapascals (MPa). The data were confirmed to be normally distributed using the Kolmogorov-Smirnov test. One-way ANOVA and Tukey’s post hoc test were used to compare SBS values among groups using SPSS 16.00 software (Microsoft, IL, USA).

RESULTS

Descriptive statistics including the mean and standard deviation values are presented in Table 1. As shown in Table 1, maximum amount of SBS belonged to group two (sandblast) (7.81±1.02 MPa), followed in a decreasing order by group four (2 W laser) (6.95±0.87 MPa), group three (1 W laser) (6.87±0.92 MPa) and group one (HF acid) (5.84±0.78 MPa) (P=0.05).

Table 1.

The mean shear bond strength of brackets to zirconia (MPa) (descriptive analysis of the groups)

Groups N Mean Std. Deviation Std. Error 95% Confidence Interval for Mean

Lower Bound Upper Bound
HF 18 5.8444 .78141 .18418 5.4559 6.2330
Sandblast 18 7.8122 1.02553 .24172 7.3022 8.3222
1W Laser 18 6.8789 .92454 .21792 6.4191 7.3387
2W Laser 18 6.9508 .87670 .20664 6.5149 7.3868
Total 72 6.8716 1.13142 .13334 6.6057 7.1375

Furthermore, the narrow range of the confidence interval in the study groups implies that data were not widely scattered. In order to compare the mean values of SBS among the study groups, ANOVA was used, which revealed significant differences among the groups (Table 2).

Table 2.

ANOVA of the samples

ANOVA

SBS Sum of Squares Difference Mean Square F Sig.
Between Groups* 35.031 3 11.677 14.215 .000
Within Groups 55.857 68 .821
*:

The mean difference is significant at the 0.05 level.

Multiple comparisons among groups were done by means of Tukey’s post hoc test (Table 3), which showed significantly different SBS values among the groups (p≤0.029) except between laser groups (P=0.995).

Table 3.

Mean difference of shear bond strength among groups (Tukey’s test)

(I) Group (J) Group Mean Difference (I-J) Std. Error Sig.
HFa Sandblastb −1.96778* .30211 .000
Laser 1wc −1.03444* .30211 .006
Laser 2wd −1.10639* .30211 .003

Sandblasta HFb 1.96778* .30211 .000
Laser 1wc .93333* .30211 .015
Laser 2wd .86139* .30211 .029

Laser 1Wa HFb 1.03444* .30211 .006
Sandblastc −.93333* .30211 .015
Laser 2wa −.07194 .30211 .995

Laser 2Wa HFb 1.10639* .30211 .003
Sandblastc −.86139* .30211 .029
Laser 1wa .07194 .30211 .995
*

Groups with the same superscripted letters are not significantly different (P>0.05)

DISCUSSION

In this study, the effects of four surface preparation methods on the SBS values of metal brackets to zirconia surfaces were compared. The results of this study revealed that sand-blasted specimens possessed the highest SBS followed by 2W and 1 W Er: YAG laser irradiation and 9.6% HF acid etched groups, respectively.

Surface preparation by laser, known as laser etching, generates heat, which creates porosities on the zirconia surface and provides mechanical retention at the zirconium-composite interface [5].

In the current study, such etching pattern was observed in electron microscopic examination of lased specimens. Since silane application after different surface conditioning methods increases bond strength [6,7], it was applied to prepared zirconia surfaces before bracket bonding in all four study groups.

As increasing temperature adversely affects the mechanical properties of zirconia ceramics, lower power outputs of Er: YAG laser were used in the current study. Heat generation as a consequence of laser irradiation leads to phase change of ceramics [8]. Higher power outputs cause greater material destruction and are therefore inappropriate for surface conditioning [9]. Our pilot study and electron microscopic examination revealed that 4 W Er: YAG laser irradiation caused burning of zirconia surface and produced micro-cracks on it; while no evidence of micro-crack formation was observed in specimens lased with 1W and 2W laser. A study conducted by Ural and coworkers on the effects of four different sizes of aluminum oxide particles on the bond strength of resin cements to zirconium cores showed that 110 μm particles provided higher bond strength [10]. This finding was further supported by Kulunk and coworkers [11]. Therefore, 110 μm aluminum oxide particles were chosen for sandblasting of the zirconia surface in the current study.

As stated earlier, no previous research has evaluated different zirconium surface preparation methods and their effects on the SBS of brackets. However, similar studies have been done on porcelain crowns. For instance, Yassaei et al. compared the effect of Er: YAG laser etching (with power outputs of 1.6, 2, and 3 W) with 9.6% HF acid etching on SBS of metal brackets to porcelain discs and found insignificant differences between the methods used [4]. However, they did not assess sand-blasting. In another study conducted by Akova et al, it was reported that HF acid etching with silane application resulted in the highest bond strength, which again differs from our findings. They also observed that sandblasting and silane application led to higher bond strength compared to Er: YAG laser, which is similar to our result [5].

Ahmad Akhoundi et al. evaluated the tensile bond strength of metal brackets to glazed ceramic surfaces with different surface conditioning techniques including HF acid etching following priming with adhesive and bonding agent alone, and another group was treated with 35% phosphoric acid followed by ceramic primer and adhesive application. They concluded that phosphoric acid can be used instead of HF acid for bonding brackets to the glazed ceramic restorations with adequate tensile bond strength [14].

In our study, we did not use phosphoric acid but we concluded that sandblasting and erbium laser can be used instead of HF acid etching. Another studies by Ahmad Akhoundi et al, also confirms the results of the latter study [12,13].

In another study Ahmad Akhoundi et al. compared conventional orthodontic bonding resin and nano-filled composite. They observed less damage to feldspathic porcelain when the nano-filled composite was used to bond brackets. Thus, they suggested the use of nano-filled composite resins for bonding brackets to feldspathic porcelain restorations [14]. However, it should be noted that the aforementioned studies were conducted on porcelain.

Akin et al. assessed the SBS of zirconia crowns to dental cements and concluded that the specimens lased with 1 W Er: YAG laser had significantly higher bond strength in comparison with the control group [15]. This finding was one of the reasons for choosing Er: YAG laser and 1W power output to prepare the zirconia surfaces in the current study. Murthy et al, also evaluated the SBS of zirconium crowns prepared with five different surface treatments to autopolymerizing resin and concluded that the CO2 laser caused the highest SBS followed by the HF acid etching and sandblasting with 110 μm alumina [16]. We did not use CO2 laser and in our study, the SBS of sandblasting was higher than that of HF acid etching.

Kasraei et al. assessed the CO2 laser surface treatment and concluded that this method significantly increased the SBS of resin cement to zirconia ceramic compared to the control group [17]. Thus, laser irradiation is one of the best methods of surface treatment.

Arami et al. assessed the SBS of the repair composite resin to zirconia ceramic by different surface treatments and concluded that air abrasion with Al2O3 particles was the most effective method for conditioning of zirconia ceramic surfaces and this finding is consistent with our result [18]. Although we did not use Nd: YAG laser, Arami et al. showed that Er: YAG laser with 2W power was superior to Nd: YAG laser with 1.5W power in terms of efficacy [18].

Uludamar et al. showed that sandblasted zirconia crowns had higher SBS compared to Er: YAG irradiated samples and also bur conditioned specimens. This finding is corroborated by the results of our study; although we did not have bur-conditioned samples [19].

Akyil et al. evaluated nine different surface treatment methods on 141 zirconia samples and found that the highest bond strength between resin cements and zirconia crowns was achieved with sandblasting and silane application. They stated that Er: YAG and CO2 lasers can be suitable alternatives to sandblasting [20] and this is further supported by the results of the current study. In a similar study, Cavalcanti concluded that higher SBS to resin cement could be attained using sandblasting plus metal primer application compared to Er: YAG laser irradiation [8]. As mentioned earlier, all the above-mentioned studies evaluated the bond strength of zirconia crowns to dental cements or enamel surfaces and no research was found on the SBS of orthodontic brackets to zirconium restorations.

Limitations

Because of economic issues and limitations due to sanction, zirconium blocks were used instead of 72 separate zirconium samples. The present study showed that using one block of zirconium and trimming it into four surfaces for bracket bonding not only had no adverse effects on the results, but also produced a uniform surface.

CONCLUSION

The results of the present study showed that sandblasting of zirconium surface led to the highest SBS values in bracket bonding followed by 2W laser, 1W laser, and HF acid etching in a descending order. It was concluded that zirconium surface treatment with sand-blasting and 1W and 2W laser irradiation was safe and provided higher SBS values in comparison with HF acid etching. Lower power outputs of laser did not cause zirconium surface damage and provided appropriate SBS values.

ACKNOWLEDGMENTS

The authors would like to thank Dr. Mahjube Goldani Moghadam and Rafieh Saadat.

REFERENCES

  • 1-. Silva NR, Sailer I, Zhang Y, Coelho PG, Guess PC, Zembic A, et al. Performance of zirconia for dental healthcare. Materials 2010; 3(2): 863– 896. [Google Scholar]
  • 2-. Visuri SR, Gilbert JL, Wright DD, Wigdor HA, Walsh JT., Jr. Shear strength of composite bonded to Er: YAG laser-prepared dentin. J Dent Res. 1996. January; 75(1): 599– 605. [DOI] [PubMed] [Google Scholar]
  • 3-. Vijayaraghavan R, Rao VA, Reddy NV, Krishnakumar R, Sugumaran DK, Mohan G. Assessment and comparison of microleakage of a fluoride-releasing sealant after acid etching and Er: YAG laser treatment–An in vitro study. Contemp Clin Dent. 2012. January; 3(1): 64– 8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4-. Yassaei S, Moradi F, Aghili H, Kamran MH. Shear bond strength of orthodontic brackets bonded to porcelain following etching with Er:YAG laser versus hydrofluoric acid. Orthodontics (Chic.). 2013; 14(1): e82– 7. [DOI] [PubMed] [Google Scholar]
  • 5-. Akova T, Yoldas O, Toroglu MS, Uysal H. Porcelain surface treatment by laser for bracket-porcelain bonding. Am J Orthod Dentofacial Orthop. 2005. November; 128(5): 630– 7. [DOI] [PubMed] [Google Scholar]
  • 6-. Kocadereli I, Canay S, Akça K. Tensile bond strength of ceramic orthodontic brackets bonded to porcelain surfaces. Am J Orthod Dentofacial Orthop. 2001. June; 119(6): 617– 20. [DOI] [PubMed] [Google Scholar]
  • 7-. Cochran D, O’Keefe KL, Turner DT, Powers JM. Bond strength of orthodontic composite cement to treated porcelain. Am J Orthod Dentofacial Orthop. 1997. March; 111(3): 297– 300. [DOI] [PubMed] [Google Scholar]
  • 8-. Cavalcanti AN, Foxton RM, Watson TF, Oliveira MT, Giannini M, Marchi GM. Bond strength of resin cements to a zirconia ceramic with different surface treatments. Oper Dent. 2009. May-Jun; 34(3): 280– 7. [DOI] [PubMed] [Google Scholar]
  • 9-. Cavalcanti AN, Pilecki P, Foxton RM, Watson TF, Oliveira MT, Gianinni M, et al. Evaluation of the surface roughness and morphologic features of Y-TZP ceramics after different surface treatments. Photomed Laser Surg. 2009. June; 27(3): 473– 9. [DOI] [PubMed] [Google Scholar]
  • 10-. Ural Ç, Külünk T, Külünk S, Kurt M. The effect of laser treatment on bonding between zirconia ceramic surface and resin cement. Acta Odontol Scand. 2010. November; 68(6): 354– 9. [DOI] [PubMed] [Google Scholar]
  • 11-. Kulunk S, Kulunk T, Ural C, Kurt M, Baba S. Effect of air abrasion particles on the bond strength of adhesive resin cement to zirconia core. Acta Odontol Scand. 2011. March; 69(2): 88– 94. [DOI] [PubMed] [Google Scholar]
  • 12-. Akhoundi MA, Kamel MR, Hashemi SM, Imani M. Tensile bond strength of metal bracket bonding to glazed ceramic surfaces with different surface conditionings. J Dent (Tehran). 2011. Fall; 8(4): 201– 8. [PMC free article] [PubMed] [Google Scholar]
  • 13-. Ahmad Akhoundi M, Rahmati Kamel M, Hooshmand T, Harririan I, Kharazi Fard M, Noroozi H. Assessment of Bond Strength between Metal Brackets and Non-Glazed Ceramic in Different Surface Treatment Methods. J Dent (Tehran). 2010. Spring; 7(2): 64– 70. [PMC free article] [PubMed] [Google Scholar]
  • 14-. Ahmad Akhoundi M, Aghajani F, Chalipa J, Sadrhaghighi A. Effect of Adhesive Type on the Shear Bond Strength of Metal Brackets to Two Ceramic Substrates. J Dent (Tehran). 2014. March; 11(2): 216– 24. [PMC free article] [PubMed] [Google Scholar]
  • 15-. Akin H, Tugut F, Akin GE, Guney U, Mutaf B. Effect of Er: YAG laser application on the shear bond strength and microleakage between resin cements and Y-TZP ceramics. Lasers Med Sci. 2012. March; 27(2): 333– 8. [DOI] [PubMed] [Google Scholar]
  • 16-. Murthy V, Manoharan, Balaji, Livingstone D. Effect of four surface treatment methods on the shear bond strength of resin cement to zirconia ceramics- a comparative in vitro study. J Clin Diagn Res. 2014. September; 8(9): ZC65– 8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17-. Kasraei S, Atefat M, Beheshti M, Safavi N, Mojtahedi M, Rezaei-Soufi L. Effect of surface treatment with carbon dioxide (CO2) laser on bond strength between cement resin and zircionia. J Lasers Med Sci. 2014. Summer; 5(3): 115– 20. [PMC free article] [PubMed] [Google Scholar]
  • 18-. Arami S, Hasani Tabatabaei M, Namdar F, Safavi N, Chiniforush N. Shear bond strength of the repair composite resin to zirconia ceramic by different surface treatment. J Lasers Med Sci. 2014. Fall; 5(4): 171– 5. [PMC free article] [PubMed] [Google Scholar]
  • 19-. Uludamar A, Aykent F. Bond strength of resin cements to zirconia ceramics with different surface treatments. Balk J Stom. 2012; 16(3): 173– 178. [Google Scholar]
  • 20-. Akyil MS, Uzun IH, Bayindir F. Bond strength of resin cement to yttrium-stabilized tetragonal zirconia ceramic treated with air abrasion, silica coating, and laser irradiation. Photomed Laser Surg. 2010. December; 28(6): 801– 8. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Dentistry (Tehran, Iran) are provided here courtesy of Tehran University of Medical Sciences

RESOURCES