Table 1.
Indicators | Benchmarks | Our study |
---|---|---|
Patients’ compliance | > 95% | 100% |
Coverage index | > 0.9 | 0.94 |
Rate of correspondence between implant and pre-plan | > 95% | 100% |
Rate of patient with good implant | > 90% | 92% |
Rate of needles’ changes | < 5% | 1.9% |
Rate of infection | < 5% | 0% |
Rate of bleeding and sever pain | < 15% | 8% |
Rate of low acute toxicities | < 30% | 27.3% |
Rate of high acute toxicities | < 5% | 0% |