Table 4.
Maximum miniscrew equivalent stress under 200-cN force (MPa)
| B1 | B2 | B3 | R1 | R2 | R3 | S1 | S2 | S3 | V1 | V2 | V3 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Force angle 0° | 130.58 | 131.66 | 131.19 | 132.06 | 130.58 | 132.00 | 122.85 | 122.87 | 125.04 | 122.62 | 126.91 | 124.50 |
| Force angle 45° | 107.54 | 108.40 | 104.07 | 108.63 | 105.06 | 108.72 | 93.10 | 99.01 | 103.01 | 100.60 | 100.15 | 99.91 |
| Force angle 90° | 22.56 | 22.78 | 22.58 | 22.64 | 22.57 | 22.85 | 21.49 | 21.27 | 21.54 | 20.78 | 21.43 | 21.84 |
B: Buttress thread shape, R: Reverse buttress thread shape, S: Square thread shape, V: V-shape thread shape