Skip to main content
. 2012 Nov 16;72(3):335–353. doi: 10.1007/s10874-012-9241-6

Table 1.

Measurements utilized in this study with uncertainties/accuracies and the platforms on which they were deployed

Instrument, Model Platform Measurement Uncertainty/Accuracy
TECO Inc., 49C NATIVE Surface O3 ±2 %
TECO Inc., 42C-Y NATIVE NO/NOy ±3 %
RM Young, #05103 NATIVE Wind Speed, Direction ±0.3 m/s, ±3°
RM Young, #41382 MDE Trailer Temperature, RH ±0.3 °C, ±1 % (at 23 °C)
ENSCI Corp., Model 2Z Free Balloon Ozone <10 %
Intermet, iMet-1 Free Balloon Temperature, RH, Pressure ±0.3 °C, ±5 %, ±1.8 hPa (400–1070 hPa), ±0.5 hPa (4–400 hPa)
Sigma Space, Mini-MPL NATIVE Backscattered 532 nm ±2 % for all altitudes
Teledyne, 400A MABL Surface O3 ±2 %
ScinTec, windRASS MABL Vertically Resolved Wind Speed, Direction 0.3–0.5 m/s, <1.5° (at <2.0 m/s)
Vaisala, TTS111 Tether Balloon Temperature, RH, Pressure ±0.5 °C, ±5 %, ±1.5 hPa
2B-Technologies, 205 Tether Balloon Ozone ±2 %
NCAR 4 Channel Chemiluminescence P3-B Ozone ±5 %
General Eastern, 1011B P3-B Temperature ±0.2 °C
Rosemount, 102 P3-B Dew/Frost Point ±0.6 °C
Rosemount, MADT 2014 P3-B Pressure ±0.25 hPa
TECO Inc., 49C Cessna 402B Ozone ±1.0 ppbv (estimated)
Vaisala, PTU 300 Cessna 402B Temperature, RH, Pressure ±0.2 °C, ±1 %, ±0.2 hPa (at 20 °C)
TECO Inc., 49 NOAA SRVx Surface O3 ±5 % (estimated)