Table 6. B2-microglobulin level cut-off levels that may be used to identify patients with residual renal function measured as GFR.

For various levels of GFR the cut-off β2 microglobulin level was determined that would yield a false positive rate (specificity) of 10%. For each GFR level area under the curve is shown for ROC analyses.

(GFR in ml/min/1.73m2 BSA) Number of patients with RKF ≥ level in column 1 in cohort Cut-off β2m microglobulin level (mg/L) for positive test Sensitivity Specificity AUC
1 155 ≤24.05 0.7 0.90 0.89
2 130 ≤23.65 0.76 0.90 0.92
3 104 ≤21.80 0.77 0.90 0.91
4 84 ≤20.40 0.75 0.90 0.92
5 64 ≤19.05 0.67 0.90 0.91
6 48 ≤18.85 0.71 0.90 0.93
7 29 ≤18.05 0.83 0.90 0.95
8 18 ≤17.45 0.94 0.90 0.96
9 16 ≤17.35 0.94 0.90 0.97
10 11 ≤16.70 1.00 0.90 0.98

AUC: Area Under the Curve