Skip to main content
. Author manuscript; available in PMC: 2015 Dec 3.
Published in final edited form as: IEEE Trans Ultrason Ferroelectr Freq Control. 2012 Oct;59(10):2156–2166. doi: 10.1109/TUFFC.2012.2442

Fig. 5.

Fig. 5

(a) Results from the 1-D microbubble acoustic radiation force (ARF) translation model [43]. Microbubble (MB) displacements when excited with a 6.67-μs pulse of varying excitation frequency and a PNP = 180 kPa were modeled. (b) Simulated MB displacement with varying transducer length when excited with a 1 kHz PRF, 20-cycle, 3-MHz Gaussian ramped sinusoid pulse with PNP = 180 kPa at the transducer center.