Skip to main content
. 2014 Oct 20;1(1):3–9. doi: 10.1093/rb/rbu002

Table 2.

Results of mercury intrusion porosimetry testing

Polymer concentration Percent porosity
Control 23 ± 9
0.25% 62 ± 5
1% 49 ± 2
2% 49 ± 2

Three scaffolds were used per group. Porosimetry shows hybrid scaffolds maintained high porosity after nanofiber precipitation procedure. Maintaining high porosity has been shown to be critical in nutrient and waste exchange.