Skip to main content
. 2015 Dec 8;5:17914. doi: 10.1038/srep17914

Table 6. Summary of outcomes of the three studies evaluating individualized preformed implants.

Study % of patients experiencing residual diplopia Enophthalmos Complications
Nkenke22 N/A Reduction in Enophthalmos (mm) ± SD Assisted: 3.25 ± 1.44 Control: 3.88 ± 1.23 (p = 0.31) Assisted: 1 reduced vision, 2 suspected retrobulbar hematoma Control: 2 suspected retrobulbar hematoma (p = N.S.)
Scolozzi23 N/A Reduction in Enophthalmos (mm) ± SD Assisted: 1.5 ± 1.58 Control: 1.8 ± 1.61 (p = 0.79) N/A
Guo24 Assisted: 17% Control: 88% (p = 0.0042) Assisted: 21%* Control: 50%* (p = 0.04)* N/A

N/A = not available; N.S. = non-significant; *percentage of patients having residual enophthalmos; *exophthalmometry data not reported; SD = standard deviation.