Skip to main content
. 2015 Aug 21;22:19887–19895. doi: 10.1007/s11356-015-5192-1

Table 3.

Comparison of different silicone rubber pre-clean-up methods regarding solvent and time

Clean-up method According to reference Total solvent (mL) Time (h) Swelling (%) Release of oligomers (%)
Soxhlet extraction ethylacetate Smedes and Booij (2012) 400 100 92 2.5
Extraction ethylacetate Shahpoury and Hageman (2013) 400 48 76 2.4
Extraction n-hexane/acetone (3:1) Schäfer et al.(2010) 800 96 124 2.5
ASE n-hexane/acetone (1:1) This study 169 1.2 42 2.2

Results of experimental approach using different clean-up methods in regard to swelling and the associated silicone oligomer release in %