Table 2.

Pearls and Pitfalls of Procedure

Reason
Pearls
 Do not use artery clip to open capsule Allows air to dissipate into soft tissues
 Use low-pressure air to insufflate joint Expands working space safely
 Use intermittent low-pressure suction Prevents collapse of working space
 Point shaver blade away from camera Prevents coating of camera with debris
 Use irrigation with radiofrequency probe Avoids heating of chondral surfaces
 Use retractors liberally Helps maintain safe working space
 Use intermittent irrigation and suction Efficiently clears bony debris
 Irrigate joint at end of procedure Minimizes infection risk
Pitfalls
 Avoid performing aggressive suction Collapses working space and draws in neurovascular structures
 Avoid making multiple passes when entering joint Allows air to dissipate into soft tissues
 Avoid using air insufflation in acute fractures May predispose to air embolus due to exposed vascular surfaces