Skip to main content
. 2015 Sep 16;9(3):181–187. doi: 10.15171/joddd.2015.033

Table 2. Means and standard deviations (SD) of the repair bond strength values (in MPa) in the study groups .

Composite resin Adhesive system mean SD N
Methacrylated-based composite resin (Z250) Adper Single Bond 2 19.18a 9.11 26
Clearfil SE Bond 10.48b 8.95 26
Silorane Adhesive 21.33a 6.66 26
Silorane-based composite resin (Filtek ‏ Silorane) Adper Single Bond 2 17.64a 7.33 26
Clearfil SE Bond 11.63b 5.98 26
Silorane Adhesive 19.78a 8.57 26
a,b - There is no significant statistic differences between similar characters.