Table 2. Means and standard deviations (SD) of the repair bond strength values (in MPa) in the study groups .
| Composite resin | Adhesive system | mean | SD | N |
| Methacrylated-based composite resin (Z250) | Adper Single Bond 2 | 19.18a | 9.11 | 26 |
| Clearfil SE Bond | 10.48b | 8.95 | 26 | |
| Silorane Adhesive | 21.33a | 6.66 | 26 | |
| Silorane-based composite resin (Filtek Silorane) | Adper Single Bond 2 | 17.64a | 7.33 | 26 |
| Clearfil SE Bond | 11.63b | 5.98 | 26 | |
| Silorane Adhesive | 19.78a | 8.57 | 26 | |
| a,b - There is no significant statistic differences between similar characters. | ||||