Skip to main content
. 2015 Dec 16;10(12):e0144608. doi: 10.1371/journal.pone.0144608

Table 1. Binary and quantitative test responses for the PCR tests performed in bulk tank milk (PCR BTM) and indoor dust samples (PCR DUST) according to the stratified population.

PCR BTM (n = 380) and PCR DUST (n = 380) tests were performed in 95 dairy cattle herds in the Finistère department, France between November 2012 and April 2014.

Test Test
PCR BTM PCR DUST Total PCR BTM PCR DUST
Binary response (+ positive;—negative) Quantitative response a (Q1,median,Q3)
+ + 146 642,4494,16140 2,6,48
+ - 48 240,1704,10020 -
- + 70 - 1,3,15
- - 116 - -
Total 380 514,3604,14280 1,5,35

a calculated among positive test responses