Table 5.
Bending constants KC from simulation (in three different units) and four different experimental method (all in J); standard errors for the simulations are given in parentheses.
| Lipid | Simulation
 | 
kBT | kcal/mol | Experiment (10−20 J)
 | 
|||
|---|---|---|---|---|---|---|---|
| 10−20 J | PAa | X-ray | NSEb | Flicker | |||
| DPPC | 15.8 (0.4) | 35.4 | 22.7 | 6.7d | 15.0i | ||
| DMPC | 12.2 (0.5) | 29.3 | 17.6 | 5.6c | 6.6e | 8.2h | 13.0i | 
| DOPC | 11.8 (0.4) | 28.8 | 17.0 | 8.5c | 8.3f | 10.9j | |
| DNPC | 22.0 (0.7) | 52.6 | 31.7 | ||||
| DOPE | 11.8 (0.3) | 28.7 | 17.0 | ||||
| POPC | 13.2 (0.4) | 31.7 | 19.1 | 8.5g | 8.6h | ||
| PDPC | 9.6 (0.1) | 23.1 | 13.9 | ||||
| POPE | 13.3 (0.6) | 31.2 | 19.2 | ||||
| PDPE | 9.9 (0.6) | 23.6 | 14.2 | ||||
| SDPE | 10.6 (0.4) | 25.4 | 15.3 | ||||
| PSM | 27.8 (0.8) | 62.7 | 40.0 | ||||
| POPG | 11.3 (0.6) | 26.9 | 16.2 | ||||
pipette aspiration (PA)
neutron spin echo (NSE)
(Guler et al., 2009)
(Kučerka et al., 2005)
(Kucerka et al., 2005)
(Mell et al., 2013)
(Fernandezpuente et al., 1994)
(Gracia et al., 2010).