Published in final edited form as: Phys Med Biol. 2015 Jun 17;60(13):5083–5101. doi: 10.1088/0031-9155/60/13/5083

Table 6.

Acquisition parameters and observer performance for the optimized and clinical dual isotope protocols.

Optimized protocol
Clinical protocol
Acquisition type: Simultaneous Separateb Separate
Acquisition parameters:
(a) Injected activities (mCi):
    Tc-99m 5.9–10a 5.9–18.2a 30
    Tl-201 2–2.25a 1.5–2.25a 3
    Relative injected activity 2.6–5a 2.6–12.1a 10
    Total effective dose (mSv) 13.5 13.5 27.5
(b) Energy window width (%):
    Tc-99m 20 20 20
    Tl-201 16.6–22.2a 11.1–22.2a 27.8
2-class IO performance:
(a) Rest and stress image qualities
    Rest Tl-201 0.819 0.751 0.792
    Stress Tc-99m 0.938 0.951 0.953
(b) Pairwise comparison between the 3 classes
    Normal Versus Fixed 0.949 0.960 0.961
    Normal Versus Reversible 0.919 0.944 0.947
    Reversible Versus Fixed 0.892 0.862 0.875
3-class IO performance:
    VUS 0.805 ± 0.01 0.809 ± 0.01 0.824 ± 0.008
a

Range of optimal acquisition parameter.

b

Note the dependence of optimal Tl-201 injected activity, (and thus Tc-99m activity) and Tl-201 energy window width.