Skip to main content
. 2015 Dec;26(1):159–172. doi: 10.1016/j.media.2015.08.012

Fig. B.1.

Fig. B.1

Comparison of pressure differences over the cardiac cycle computed using a boundary flux computed from the outlet plane of the ROI (Λ) or from the outlet and walls surface (Λ˜). CFD pressure difference (solid black line), WERP average pressure difference over 100 simulation tests (dashed black line) and WERP 99% confidence interval (grey filled color).