Table 2.
Summary of data for mechanical tests on cpTi (II) following sol–gel treatment and annealing at different temperatures, including an untreated cpTi (II) control
Mechanical test | Maximum annealing temperature | |||
---|---|---|---|---|
Untreated cpTi (II) (control) | 300 °C | 500 °C | 700 °C | |
Total length of abrasive scaring (mm) | 38.3 ± 7.8 | 34.7 ± 7.9 | 32.4 ± 4.8 | 16.2 ± 2.3 |
Micro hardness (HV0.01) | 151.8 ± 6.9 | 152.1 ± 7.7 | 149.9 ± 5.8 | 455.8 ± 54.2 |
Maximum flexural modulus (MPa) | 841.1 ± 18.8 | 854.3 ± 32.5 | 836.9 ± 37.9 | 912.4 ± 38.7 |
Pull stress at point of failure (MPa) | 6.8 ± 0.8 | 10.2 ± 0.6 | 9.1 ± 3.0 | 7.0 ± 0.8 |
Standard deviation from three trials per test are displayed next to the average value for each sample in each test