Table 2.

Table 2.1. Optimized s value for rotamer libraries of size ranging from 0.2Å to 5.0Å, plus the
all torsion rotamer library. The s values for that gives the best RMSD value is listed.
Library Number of
Rotamers
Unmodified
Potential
(RMSD,Å)
Best s value Best RMSD
(Å)
0.2Å 14755 0.536 1.3 0.468
0.6Å 3195 0.710 1.1 0.564
1.0Å 1014 0.857 1.2 0.665
1.4Å 378 0.958 1.1 0.753
1.8Å 214 1.064 0.9 0.885
2.2Å 136 1.343 0.8 1.175
3.0Å 84 1.624 0.7 1.487
5.0Å 44 1.890 0.7 1.860
All Torsion 382 0.937 0.9 0.800
Table 2.2. Effect of s values on χ1/χ1+2 accuracy. Rotamer libraries of diversity ranging from
0.2Å to 5.0Å, plus the all torsion rotamer library are used. The best χ1+2 accuracy is used to
determine the most effective scaling factor c. A χ angle is considered correct if within 40° of
the corresponding χ angle in the crystal sidechain conformation.
Library Number of
Rotamers
χ1/χ1+2 accuracy
from unmodified
scoring function
Best scaling
factor s
χ1/χ1+2
accuracy using
best s value
0.2Å 14755 95.0% / 91.8% 1.3 96.3% / 93.4%
0.6Å 3195 92.6% / 87.7% 1.1 95.6% / 92.1%
1.0Å 1014 90.0% / 83.4% 1.2 95.3% / 90.4%
1.4Å 378 87.8% / 80.0% 1.2 94.7% / 88.9%
1.8Å 214 84.3% / 75.6% 1.2 91.5% / 83.8%
2.2Å 136 71.9% / 61.0% 0.8 79.1% / 68.0%
3.0Å 84 63.4% / 54.1% 0.7 68.4% / 58.9%
5.0Å 44 53.2% / 44.9% 0.7 54.9% / 45.8%
All Torsion 382 89.6% / 81.3% 1.1 93.3% / 86.8%