. 2015 Dec 11;32(6):421–425. doi: 10.5114/pdia.2015.56096

Table 2.

Technical properties of inhalation allergen chambers (based on Day et al.) [12]

Parameters VCC (Vienna University Clinic) [11] EEU (UK) [12] Allergy Center (Vienna) [13] VCC (Copenhagen) [14] VCC (Atlanta) [15] VCC (Hannover) [16]
Area [m2] 13.78 303 21 5 360 47
Height [m] 2.7 2.74 2.8 2.6 3.6 2.8
Number of subjects 14 160 24 1 150 18–25
Type of room A custom designed room A custom designed room in a hospital A custom designed room A portable tent A custom designed room A custom designed room
Ventilation system Air pumped into the room through a ceiling-mounted system and removed through the 100% of outdoor air filtered by Farr 30/30 and Farr Riga-Flo 200 filters Air pumped into the room through a ceiling-mounted system and removed through the floor Vent filters, application of an allergen by means of a diffuser at a rate of 4000–6000 l/h Outdoor ventilation at a rate of ≥ 5 cfm/person Outdoor ventilation with a HEPA filter
Dose 1500 seeds/m3 (700–110 ng/m3) 20–110 ng/m3 Der p 1 3500 ±500 seeds/m3 1400 seeds/m3 90 ng/m3 Der p 1 50–100 ng/m3 Der p 1 3000–4500 seeds/m3 1000–8000 seeds/m3
Allergen concentration monitoring method Bucard device, every 5 min Rotorom device, every 30 min Every 5 min A portable measurement device installed in the filter Bucard device, every 30 min Rotorom device, every 30 min; a particle counter laser device, every minute