. 2015 Oct 13;5(4):618–646. doi: 10.3390/bios5040618

Figure 6.

Figure 6

(a,b) 1 kHz impedances of individual PEDOT/MWCNT/Dex-coated electrodes chronically submerged in sterile PBS over 11 days. Electrodes in (a) were not subjected to daily CV, while those in (b) were subjected to daily CV. Electrodes in (b) are numerically labeled for reference; (c,d) Representative Nyquist plots collected at days 1, 7, and 11 for a non-CV-stimulated electrode (c) and a CV-stimulated electrode that exhibited high day-11 impedance ((d), Electrode 2). Note that non-CV-stimulated electrodes exhibited characteristic high-frequency behavior at all days, while high-impedance CV-stimulated electrodes exhibited a progressive “straightening” and loss of characteristic high-frequency behavior.