Skip to main content
. 2015 Dec 12;8(6):456–462. doi: 10.1016/j.tranon.2015.10.003

Table 4.

Correlation of Radiation Dosimetric Parameters of Inner Ear with SNHL (102 Ears)

Parameters Cutoff Incidence Above Cutoff Incidence Under Cutoff P OR 95% CI
V30 62.2% 17.0% (8/47) 9.1% (5/55) .231 2.44 0.62-6.77
V40 22.0% 18.3% (11/60) 4.8% (2/42) .043 4.49 0.94-21.44
V50 2.4% 19.0% (11/58) 4.5% (2/44) .031 4.92 1.03-23.46
V60 0.16% 15.6% (5/32) 11.4% (8/70) .555 1.44 0.43-4.79
V70 6.1% 10.5% (2/19) 13.3% (11/83) 1.000 0.77 0.16-3.80
Mean dose 35.0Gy 17.0% (8/47) 9.1% (5/55) .231 2.05 0.62-6.77
Dmin 18.8Gy 16.4% (9/55) 8.5% (4/47) .236 2.10 0.60-7.33
Dmax 56.8Gy 19.6% (10/51) 5.9% (3/51) .038 3.90 1.01-15.14
Median dose 36.8Gy 20.4% (11/54) 4.2% (2/48) .014 5.88 1.23-28.08
EUD (a= 16.7) 43.5Gy 21.1% (12/57) 2.2% (1/45) .005 11.7 1.46-96.01
D0.1 ml 48.0Gy 19.4% (12/62) 2.5% (1/40) .013 9.36 1.17-75.11
D0.035 ml 51.4Gy 19.6% (11/56) 4.3% (2/46) .021 5.38 1.13-25.67

Fisher’s exact test was used.