Skip to main content
. 2015 Oct 20;290(50):30018–30029. doi: 10.1074/jbc.M115.679852

TABLE 5.

Binding kinetics of anti-B7-H3 IgG constructs

Error values are shown as S.E., and Rmax represents the maximum response units (RU) measured for the highest concentration of each sample.

Antibodies 4Ig-B7-H3
2Ig-B7-H3
ka kd KD Rmax χ2 ka kd KD Rmax χ2
s1m1 s1 nm RU RU2 s1m1 s1 nm RU RU2
m8H9 1.846 ± 0.006 × 104 1.650 ± 0.002 × 10−4 8.9 87.34 0.153 2.776 ± 0.011 × 104 2.244 ± 0.019 × 10−5 0.81 76.5 0.150
ch8H9 2.834 ± 0.030 × 104 2.180 ± 0.010 × 10−4 7.7 66.49 2.69 3.210 ± 0.025 × 104 8.729 ± 0.046 × 10−5 2.7 68.51 0.724
ch8H9-6m 3.349 ± 0.014 × 104 1.229 ± 0.002 × 10−4 3.7 107.1 0.550 6.890 ± 0.018 × 104 4.254 ± 0.026 × 10−5 0.62 96.84 0.844
hu8H9 2.046 ± 0.052 × 104 6.770 ± 0.023 × 10−4 33 41.55 0.472 1.347 ± 0.020 × 104 6.069 ± 0.009 × 10−4 45 57.89 0.117
hu8H9-6m 2.342 ± 0.020 × 104 2.979 ± 0.005 × 10−4 13 82.60 0.572 3.394 ± 0.011 × 104 1.711 ± 0.002 × 10−4 5.0 80.61 0.211