TABLE 5.
Binding kinetics of anti-B7-H3 IgG constructs
Error values are shown as S.E., and Rmax represents the maximum response units (RU) measured for the highest concentration of each sample.
Antibodies | 4Ig-B7-H3 |
2Ig-B7-H3 |
||||||||
---|---|---|---|---|---|---|---|---|---|---|
ka | kd | KD | Rmax | χ2 | ka | kd | KD | Rmax | χ2 | |
s−1m−1 | s−1 | nm | RU | RU2 | s−1m−1 | s−1 | nm | RU | RU2 | |
m8H9 | 1.846 ± 0.006 × 104 | 1.650 ± 0.002 × 10−4 | 8.9 | 87.34 | 0.153 | 2.776 ± 0.011 × 104 | 2.244 ± 0.019 × 10−5 | 0.81 | 76.5 | 0.150 |
ch8H9 | 2.834 ± 0.030 × 104 | 2.180 ± 0.010 × 10−4 | 7.7 | 66.49 | 2.69 | 3.210 ± 0.025 × 104 | 8.729 ± 0.046 × 10−5 | 2.7 | 68.51 | 0.724 |
ch8H9-6m | 3.349 ± 0.014 × 104 | 1.229 ± 0.002 × 10−4 | 3.7 | 107.1 | 0.550 | 6.890 ± 0.018 × 104 | 4.254 ± 0.026 × 10−5 | 0.62 | 96.84 | 0.844 |
hu8H9 | 2.046 ± 0.052 × 104 | 6.770 ± 0.023 × 10−4 | 33 | 41.55 | 0.472 | 1.347 ± 0.020 × 104 | 6.069 ± 0.009 × 10−4 | 45 | 57.89 | 0.117 |
hu8H9-6m | 2.342 ± 0.020 × 104 | 2.979 ± 0.005 × 10−4 | 13 | 82.60 | 0.572 | 3.394 ± 0.011 × 104 | 1.711 ± 0.002 × 10−4 | 5.0 | 80.61 | 0.211 |