Figure 3. Displacement and strain–precision and effect of smoothing on displacement fields.

Figure 3

dualMRI experiments of a silicone imaging phantom were repeated at three different spatial resolutions to permit the calculation of displacement (A) and strain (B) precision. Precision improved with smoothing at all spatial resolutions but leveled off with less smoothing at coarser spatial resolutions, which also provided higher signal-to-noise ratios. Noise was added to simulated displacements of idealized cartilage-cartilage contact (C) to test the effect of smoothing in thin cartilage geometries. Displacement fields retained key features despite a general “flattening” of displacement gradients that is expected with smoothing (D).