Skip to main content
. Author manuscript; available in PMC: 2016 Jan 11.
Published in final edited form as: Med Care. 2015 Jan;53(1):71–78. doi: 10.1097/MLR.0000000000000259

TABLE A1.

Results of the Lag Time Analysis to Determine the Association Between Adoption of the Surgical Robot and Changes in the Proportion of Partial Nephrectomy

Hospital Characteristics Marginal Change in Proportion
of Partial Nephrectomy as
Compared With Proportion
in 2001 (95% CI)
P
Robot acquisition 2001–2003 In 2005: +26.0% (5.5–46.4) 0.01
In 2008: +30.3% (0.30–60.4) < 0.01
Robot acquisition 2005–2007 In 2008: +20.0% (6.8–33.1) 0.048

CI indicates confidence interval.