Observations on glutaraldehyde-treated heterologous cardiac valves.

E Bodnar, E G Olsen, D N Ross
PMCID: PMC471199  PMID: 120617

Abstract

Recent publications on commercial porcine bioprosthetic cardiac valves have stated that the endothelium disappears during the glutaraldehyde processing and that in many cases histological evidence of early tissue deterioration was found. Our experiences have shown that porcine aortic valves can be processed in glutaraldehyde without loss of the integrity of the endothelium and with the development of optimum collagen fibre structure. The valve mounted in a Dacron tube is not restricted in diameter and performs well under biological conditions up to a period of six months.

Full text

PDF
794

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Angell W. W., Angell J. D., Sywak A. Section of tissue or prosthetic valve. A five-year prospective, randomized comparison. J Thorac Cardiovasc Surg. 1977 Jan;73(1):43–53. [PubMed] [Google Scholar]
  2. Ashraf M., Bloor C. M. Structural alterations of the porcine heterograft after various durations of implantation. Am J Cardiol. 1978 Jun;41(7):1185–1190. doi: 10.1016/0002-9149(78)90874-3. [DOI] [PubMed] [Google Scholar]
  3. Carpentier A., Lemaigre G., Robert L., Carpentier S., Dubost C. Biological factors affecting long-term results of valvular heterografts. J Thorac Cardiovasc Surg. 1969 Oct;58(4):467–483. [PubMed] [Google Scholar]
  4. Ferrans V. J., Spray T. L., Billingham M. E., Roberts W. C. Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients. Am J Cardiol. 1978 Jun;41(7):1159–1184. doi: 10.1016/0002-9149(78)90873-1. [DOI] [PubMed] [Google Scholar]
  5. Fishbein M. C., Gissen S. A., Collins J. J., Jr, Barsamian E. M., Cohn L. H. Pathologic findings after cardiac valve replacement with glutaraldehyde-fixed porcine valves. Am J Cardiol. 1977 Sep;40(3):331–337. doi: 10.1016/0002-9149(77)90154-0. [DOI] [PubMed] [Google Scholar]
  6. Ionescu M. I., Tandon A. P., Mary D. A., Abid A. Heart valve replacement with the Ionescu-Shiley pericardial xenograft. J Thorac Cardiovasc Surg. 1977 Jan;73(1):31–42. [PubMed] [Google Scholar]
  7. LENDRUM A. C., FRASER D. S., SLIDDERS W., HENDERSON R. Studies on the character and staining of fibrin. J Clin Pathol. 1962 Sep;15:401–413. doi: 10.1136/jcp.15.5.401. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Oyer P. E., Stinson E. B., Griepp R. B., Shumway N. E. Valve replacement with the Starr-Edwards and Hancock prostheses: comparative analysis of late morbidity and mortality. Ann Surg. 1977 Sep;186(3):301–309. doi: 10.1097/00000658-197709000-00008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Spray T. L., Roberts W. C. Structural changes in porcine xenografts used as substitute cardiac valves. Gross and histologic observations in 51 glutaraldehyde-preserved Hancock valves in 41 patients. Am J Cardiol. 1977 Sep;40(3):319–330. doi: 10.1016/0002-9149(77)90153-9. [DOI] [PubMed] [Google Scholar]
  10. Zuhdi N. The porcine aortic valve bioprosthesis: a significant alternative. Ann Thorac Surg. 1976 Jun;21(6):573–575. doi: 10.1016/s0003-4975(10)63935-5. [DOI] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES