Skip to main content
. Author manuscript; available in PMC: 2017 Feb 1.
Published in final edited form as: J Magn Reson Imaging. 2015 Jul 14;43(2):391–397. doi: 10.1002/jmri.25000

Table 2.

Inter-reader variability of MRR parameters estimated with the proposed software.

GFR (ml/min) RPF (ml/min) MTT (s)
Model WK CM WK CM WK CM
SD
(CV)
2.0 ± 2.0
(7.4% ± 6.4%)
3.0 ± 3.0
(8.0% ± 8.8%)
13.1 ± 12.0
(8.6% ± 7.5%)
14.7 ± 15.0
(9.2% ± 8.6%)
21 ± 20
(8.6% ± 7.1%)
20 ± 19
(8.8% ± 8.3%)

Standard deviation (SD) values were computed from the parameter values estimated by the three readers and then were averaged across all kidneys. The coefficient of variation (CV) for a parameter is the ratio of the SD over the mean value between the three readers. WK refers to the whole-kidney model, CM to the corticomedullary model.