Table 1.
Center | Method | Diagnosis | URL (pg/ml) | Diag Accuracy | Ref. | |||
---|---|---|---|---|---|---|---|---|
P-Yes | P-No | NMN | MN | Sens | Spec | |||
NIH | HPLC | 214 | 644 | 112 | 61 | 99 % | 89 % | [8] |
Vienna | HPLC | 17 | 14 | 121 | 61 | 100 % | 100 % | [7] |
Mayo Clinic | HPLC | 56 | 445 | 165 | 99 | 96 % | 85 % | [9] |
University of Essen | RIA | 24 | 126 | 126 | 37 | 96 % | 79 % | [10] |
Sternberk Hospital | HPLC | 25 | 1 235 | 112 | 61 | 100 % | 97 % | [11] |
All Centers | – | 336 | 2 464 | – | – | 98 % | 92 % | – |
Abbreviations: P-Yes: number of patients with pheochromocytoma; P-No: number of patients in whom pheochromocytoma was excluded; URL: upper reference limits of reference intervals; NMN: normetanephrine; MN: metanephrine; Diag Accuracy: Diagnostic accuracy; Sens: Diagnostic sensitivity; Spec: Diagnostic specificity