Skip to main content
. 2015 Nov 18;2015(11):CD010983. doi: 10.1002/14651858.CD010983.pub2

3. Number of platelet transfusions and number of platelet units.

Study Intervention Number of participants in each arm Number of platelet transfusions/participant Comparison statistics P value Number of platelet units transfused/participant Comparison statistics P value
Short‐term follow‐up (up to 30 days)
Diedrich 2005 < 10 x 109/L 79 Median 4; range 0 to 32 Not reported < 0.001 Not reported Not reported Not reported
< 30 x 109/L 87 Median 10; range 0 to 48 Not reported Not reported
Heckman 1997 ≤ 10 x 109/L 37 Mean 8.4 ± SD 5.3* MD ‐3.00,
95% CI
‐5.76 to ‐0.24*
Not reported Not reported Not reported Not reported
≤ 20 x 109/L 41 Mean 11.4 ± SD 7.1* Not reported Not reported
Rebulla 1997 < 10 x 109/L 135 Mean 7.05 ± SD 4.56 MD ‐1.92,
95% CI
‐3.12 to ‐0.72
0.001 Not reported Not reported Not reported
< 20 x 109/L 120 Mean 8.97 ± SD 5.17 Not reported Not reported

*unpublished data provided by the author. The paper provided medians and ranges median 7 (5 to 11) for the standard‐trigger arm and median 11 (6 to 15) for the higher‐trigger arm.

CI = confidence interval

MD = mean difference

SD = standard deviation