Skip to main content
. 2015 Feb 12;48(1):106–114. doi: 10.4143/crt.2014.131

Table 2.

Dose-volume parameters according to radiotherapy techniques

Variable 3D-CRT (n=48) IMRT (n=29) p-value
CTV (cm3) 279.3 (89.4-1,543.3) 357.5 (89.3-762.7) 0.706
CTV
 < 300 cm3 28 (59.3) 10 (34.5) 0.043
 ≥ 300 cm3 20 (41.7) 19 (65.5)
Total lung
 Mean dose (Gy) 18.4 (9.3-28.0) 19.6 (14.6-25.2) 0.031
 V5 (%) 57.2 (29.8-72.9) 65.1 (48.4-90.0) < 0.001
 V10 (%) 48.6 (24.5-63.5) 51.8 (41.8-62.9) 0.107
 V15 (%) 40.6 (18.1-54.5) 42.3 (34.7-53.6) 0.052
 V20 (%) 32.8 (14.3-50.0) 35.6 (28.2-45.9) 0.061
Esophagus
 Maximum dose (Gy) 67.1 (55.3-74.7) 68.4 (60.0-77.3) 0.007
 Mean dose (Gy) 33.2 (12.5-55.8) 35.1 (16.1-52.0) 0.111
 V30 (%) 52.1 (15.2-87.7) 55.9 (15.8-79.6) 0.520
 V45 (%) 44.2 (3.7-74.9) 48.8 (1.2-76.5) 0.526
Spinal cord
 Maximum dose (Gy) 43.9 (10.5-57.4) 43.1 (32.3-48.4) 0.708
Heart
 Median dose (Gy) 8.6 (0.5-42.4) 16.4 (1.5-35.0) 0.001

Values are presented as median (range) or number (%). 3D-CRT, three-dimensional conformal radiotherapy; IMRT, intensity-modulated radiotherapy; CTV, clinical target volume; VD, percentage volume of organ receiving ≥ D Gy.