Skip to main content
. Author manuscript; available in PMC: 2016 Jan 21.
Published in final edited form as: Anal Chem. 2013 Aug 22;85(17):8462–8468. doi: 10.1021/ac402102j

Table 2.

Testing of porcine plasma samples spiked with vancomycin.

Spiked (μM) Found (μM) Recovery (%)
3.0 2.9 ± 0.1 97
9.0 9.3 ± 0.3 103
15 14 ± 0.4 93
30 28 ± 0.4 93
50 51 ± 0.5 102

Errors in the absorbance measurements represent ± 1 standard deviation and are for experiments performed in triplicate.