Skip to main content
. Author manuscript; available in PMC: 2016 Jan 21.
Published in final edited form as: AJR Am J Roentgenol. 2015 Oct 22;206(1):86–91. doi: 10.2214/AJR.14.14065

TABLE 4.

Comparison of Mean Scores for Confidence in Tumor Identification on 2D and 3D Fast Spin-Echo (FSE) MR Images, by Individual Radiologist and for All Readers

Technique Radiologist(s)
Reader 1 Reader 2 Reader 3 Reader 4 Reader 5 Reader 6 All

2D FSE 3.14 (1.35) 4.14 (0.95) 3.64 (1.22) 3.71 (1.27) 4.00 (0.68) 3.29 (1.38) 3.63 (1.07)
3D FSE 3.14 (1.41) 3.86 (0.77) 3.64 (1.01) 3.71 (1.07) 4.07 (0.73) 3.36 (1.22) 3.65 (1.19)
p 1.00 0.16 1.00 1.00 0.78 0.87 0.67

Note—Except where otherwise indicated, data are mean scores with SDs given in parentheses.