Table 1.
Parameter Names | Parameter Values |
---|---|
Initial energy of node (Ei) | 1000 J |
Node energy threshold (Eth) | 10 J |
Network coverage rate threshold (Cth) | 0.1 |
Energy consumption per movement distance (mu) | 1.5 J/m |
Size of information package (Mb) | 1 Kbit |
Power threshold (Pr) | 0.05 w |
Frequency of carrier acoustic signal (f) | 25 kHz |
Transmission speed of information package (Sv) | 5 kbps |
Energy spreading factor (λ) | 1.5 |
Sensing range of node (Rs) | 15 m |