Skip to main content
. 2015 Dec 7;15(12):30810–30826. doi: 10.3390/s151229831

Table 3.

A sample of some published results for the validation of underwater camera calibrations.

Technique Validation Percentage Error
Absorption [47] Length measurement of silhouettes or rods throughout the volume 0.2%–0.7%
Lens distortion grid [17] Caliper measurements of Chinook Salmon 1.5%
Absorption [6] Caliper measurements of Southern Bluefin Tuna 0.2%
Perspective shift [64] Flat reference plate and straight line re-construction 0.4%
Absorption [40] Similarity transformation between above and below water networks 0.3%
Radial lens distortion correction [72] Distances on checkerboard 0.9%–1.5%
Absorption [41] Length measurements of a rod throughout the volume 0.5%
Perspective shift [65] Flat reference plate and distance between spheres 0.4%–0.7%