Table 2.
Proposed Method | Reference [19] | |||
---|---|---|---|---|
Used image | Palmprint image | Palm-dorsum vein image | Palmprint image | Palm vein image |
Image captured from | Palm | Palm-drosum | Palm | Palm |
Capturing device | Scanner | Infrared camera | camera | Near infrared camera |
Capturing scenarios | Peg-free | Peg-free | Use docking device | Use docking device |
Sensor material | CMOS | Microbolometer | CMOS | CMOS |
Sensor type | Linear | Focal Plane Array | Focal Plane Array | Focal Plane Array |
Sensor spectral response | 380–750 nm | 8–14 μm | 380–750 nm | 750–1000 nm |
Imaging mechanism | Detect reflected visible spectrum | Detect radiated IR spectrum | Detect reflected visible spectrum | Detect reflected NIR spectrum |
Image size | 845 × 829 | 320 × 240 | 768 × 576 | 768 × 576 |